EC 20: Defrost Under-Heat With No Feedback

EC 20 means a later 600 Series freezer went into defrost, the coil did not warm enough, and the control got no signal back from the defrost circuit at the start. Left alone, frost can keep building on the coil. Sub-Zero Repair Redmond traces the heater circuit; call (425) 905-2822.

EC 20 at a glance — Sub-Zero Repair Redmond, (425) 905-2822
Means Defrost under-heat, together with no feedback from the defrost circuit when defrost started.
Check first
  • Frost or ice gathering inside the freezer compartment.
  • The freezer readout creeping above the temperature it is set to.
  • Whether EC 40 is stored as well; Sub-Zero sends the technician to EC 20 first.
Needs a technician
  • A manual defrost started with the coil cold; a compressor restarting about five minutes in points to the wire reporting back from the heater.
  • Defrost heater resistance and the defrost terminator checked, with their connections.
  • Power from the control board to the defrost circuit confirmed during a manual defrost.

Two faults in one code

EC 20 joins two conditions. Under-heat: the defrost heater did not bring the freezer coil up to temperature. No feedback: as defrost began, the control expected a signal back from the heater circuit and did not receive it. The same table keeps EC 22 for missing feedback alone and EC 24 for under-heat alone, so EC 20 is the case where both happen together.

What a working defrost does

The 600 Series freezer defrosts as needed. A heater warms the coil, the melt runs down to the water pan, and a terminator switch cuts out at 55°F (70°F on the 601F-3) to end the heat. When the heater circuit fails, frost stays on the coil and less air gets through it, and the freezer slowly warms.

Why the five minutes matter

In Sub-Zero’s test, a compressor that restarts five minutes into a manual defrost means the defrost ended early. That sends the technician to the wire carrying the heater’s signal back to the board before any part is replaced.

Evaporator fan and air duct exposed behind the opened rear panel of an empty freezer compartment

EC 20 on your display?

Sub-Zero Repair Redmond · $89 service call, deducted once the repair goes ahead · on site 0800 to 2000 hrs, all seven days

Checked by
Dean Halvorsen
Bench
sealed systems and airflow
Trade
19 yrs
Card
EPA 608 certified
Revised
Overhead view of an open machine compartment with bagged relays, a multimeter and screwdrivers on the carpet beside it

Next step

Series, readout,
then a price

Give us the model off the tag and whatever the display is showing. When the fix is a clean condenser or a reset you can do yourself, you will hear that on the phone. When it needs a technician, the visit is $89 and it comes off the repair bill; the price for the work is in writing before anything is opened.